BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//wp-events-plugin.com//6.5.2//EN
BEGIN:VEVENT
UID:38@hkie-fe.org
DTSTART;TZID=Asia/Hong_Kong:20230320T183000
DTEND;TZID=Asia/Hong_Kong:20230320T200000
DTSTAMP:20230329T105536Z
URL:https://www.hkie-fe.org/course-event/clean-agent-suppression-system-an
 d-room-integrity-test/
SUMMARY:Clean Agent Suppression System and Room Integrity Test
DESCRIPTION:/*! elementor - v3.11.5 - 14-03-2023 */\n.elementor-heading-tit
 le{padding:0\;margin:0\;line-height:1}.elementor-widget-heading .elementor
 -heading-title[class*=elementor-size-]>a{color:inherit\;font-size:inherit\
 ;line-height:inherit}.elementor-widget-heading .elementor-heading-title.el
 ementor-size-small{font-size:15px}.elementor-widget-heading .elementor-hea
 ding-title.elementor-size-medium{font-size:19px}.elementor-widget-heading 
 .elementor-heading-title.elementor-size-large{font-size:29px}.elementor-wi
 dget-heading .elementor-heading-title.elementor-size-xl{font-size:39px}.el
 ementor-widget-heading .elementor-heading-title.elementor-size-xxl{font-si
 ze:59px}About the Seminar		\n		Clean agent is a gaseous fire suppressant t
 hat is electrically non-conducting and does not leave reside after evapora
 tion. This is one of the most popular fire suppression systems adopted for
  high value equipment / goods\, such as historical artifacts &amp\; sensit
 ive electronic equipment. Since the most popular type of Clean Agent Suppr
 ession is Total Flooding System and this type of system’s key performanc
 e is highly dependent on the enclosure integrity (i.e. holding period afte
 r discharge)\, such that the examine and test of room integrity leakage in
  terms of quantitative results shall be obtained and recorded.This present
 ation will introduce the recent development and control of different suppr
 ession agents\, key parameters for total flooding system design and share 
 cases that fail to pass the room integrity test and suggested solutions to
  fulfill the holding period.		\n			Speaker		\n		Ir George LEE\, Director o
 f YOTTA Engineering Company Limited\, Hon. Secretary of The Association of
  Registered Fire Service Installation Contractors of Hong Kong Limited. Ir
  LEE with over 25 years experiences in Clean Agent Fire Extinguishing syst
 ems and specializing in engineering systems design\, such as Long Throw Sp
 rinkler system\, Watermist system\, water spray system\, drencher system a
 nd Fire monitor system. Ir LEE completed many projects in Hong Kong and Ma
 cau including Hong Kong Palace Museum\, Venetian Macau &amp\; MGM Macau.		
 \n			Official Language		\n		Cantonese supplemented with technical terms in
  English.		\n			CPD Certificates		\n		This seminar is recommended for 1.5 
 CPD hours. Attendance certificate will be issued.		\n			Registration & Enq
 uiries		\n		Free attendance but limited and priority will be given to HKIE
  and HKIFE members. Please complete the online registration form https://f
 orms.gle/D15vCBTV1V39fZX7AShould you have any further enquiry\, please con
 tact Ms. Tracy PANG by email at tracy.pang@hkife.org.